聯(lián)系方式:010-68460051
Tel:13520131150



多重電纜
GPS200 - MGTR GPS配件附件
測(cè)試引線(xiàn)組
校準(zhǔn)盒
FREJA 306 Standalone: Includes: International power cord, IEC 61850 test capability,
Transducer test capability, and test leads.
FREJA 306 Standalone: Includes: International power cord, with IEC 61850 test capability,
and test leads. Excludes: No transducer test capability
FREJA 306 Standalone: Includes: International power cord, Transducer test capability,
and test leads. Excludes: no IEC 61850 test capability
FREJA 306 Standalone: Includes: International power cord, and test leads. Excludes: no IEC
61850 test capability, no transducer test capability
FREJA 306 Standalone: Includes: International power cord and Transducer test capability.
Excludes: no IEC 61850 test capability, no test leads
FREJA 306 Standalone: Includes: International power cord, with IEC 61850 test capability.
Excludes: No transducer test capability, no test leads
FREJA 306 Standalone: Includes: International power cord. Excludes: no IEC 61850 test
capability, no transducer test capability, no test leads
Included Software – Every unit comes with the PC version of the
FREJA Local software called FREJA Remote.
訂購(gòu)信息
Description
Style Number
F306-30P2C1I1T1
F306-30P2C1I1S1
F306-30P2C1I0T1
F306-30P2C1I0S1
F306-30P2C1I0T0
F306-30P2C1I1S0
F5306-30P2C1I0S0
84835
Optional Software
84673
FREJA Win
Included Standard Accessories
Power Cord - Depending on the style number, the unit will come with one of the following,
Line cord, NEMA
90015-267
Line cord, Continental Europe with CEE 7/7 Schuko Plug
90015-268
Line cord, International color coded wire
90015-269
Line cord, United Kingdom
90015-270
Ethernet cable for interconnection to PC, 210cm (7 ft.) long (Qty. 1 ea.)
90003-594
Instruction manual (digital copy)
84624
| FREJA306繼電保護(hù)測(cè)試儀產(chǎn)品規(guī)格 | |
| 在30分鐘的預(yù)熱時(shí)間后,規(guī)格適用于電阻負(fù)載,額定電壓供應(yīng)和環(huán)境溫度+ 25°C±3°C(77°F±5.4°F)。 所有硬件數(shù)據(jù)均為滿(mǎn)量程值。規(guī)格如有更改,恕不另行通知。 | |
| 環(huán)境 | |
| 應(yīng)用領(lǐng)域 | 用于高壓變電站和工業(yè)環(huán)境。 |
|
溫度 操作 儲(chǔ)存和運(yùn)輸 濕度 |
0°C to +50°C (32°F to +122°F) -40°C to +70°C (-40°F to +158°F) 5% – 95% RH, non-condensing |
| 海拔高度 |
3000 m 全職周期可達(dá)2000米。 基于海拔大于2000米的內(nèi)部過(guò)溫保護(hù)的占空比限制。 |
| CE-marking | |
|
EMC LVD |
2004/108/EC 2006/95/EC |
| General | |
| 主輸入(標(biāo)稱(chēng)) | 100 – 240 V AC, 50 – 60 Hz |
| 能量消耗 | 1200 VA + 1500 VA (max) |
| 尺寸 |
儀器 450 x 224 x 410 mm(17.7” x 8.8” x 16.1“) 運(yùn)輸箱 610 x 345 x 660 mm(24” x 13.6” x 26”) |
| 重量 |
儀器 23 kg (50.7 lbs) 運(yùn)輸箱 12 kg (26.4 lbs) |
| 顯示 | LCD |
| 可用語(yǔ)言 | English, French, German, Spanish,Swedish |
| 測(cè)量部分 | |
| 二進(jìn)制輸入 | |
| 編號(hào)類(lèi)型 | 10 Inputs (2 groups of 5 indepen-dent)干或濕接觸275 V DC,240 VAC響應(yīng)時(shí)間補(bǔ)償 |
| 內(nèi)部解析時(shí)間 | 50 μs |
| 電隔離 | 與放大器部分電隔離。 兩個(gè)電氣分離的組:1至5和6至10 |
| 最大測(cè)試時(shí)間 | 15264 h (636 days) |
| 范圍 | 分辨率 |
| 0 - 9.9 ms | 0.1 ms |
| 10 ms - 60 min | 1 ms |
| 1 h - 15264 h | 1 s |
| 直流電流輸入, 低電平 | |
| 測(cè)試范圍 | ±20 mA |
| 分辨率 |
SW 0.1 μA HW 0.6 μA |
| 不確定度 | 0.01% typical,0.03% guaranteed (= 6 μA) |
| 直流電壓輸入,低電平 | |
| 測(cè)試范圍 | ±10 V |
| 分辨率 |
SW 0.1 mV= HW 0.3 mV |
| 不確定度 |
0.01% typical, 0.03% guaranteed (= 3 mV) |
| AC /DC輸入電流測(cè)量,高電平 | |
| 測(cè)試范圍 | ±14 A DC, 10 A AC RMS |
| 不確定度 | DC <0.1%, AC <0.3% |
| AC /DC輸入電流測(cè)量,高電平 | |
| 測(cè)試范圍 | ±220 V DC, 150 V AC RMS |
| 不確定度 | DC <0.05%, AC <0.2% |
| 測(cè)量,內(nèi)部生成值 | |
|
不確定度 電壓 AC / DC 電流 AC / DC |
<1% ±1digit <2% ±2digit |
| 進(jìn)制輸出 |
|
| 數(shù)字類(lèi)型 | 2 x 4 (NO & NC)零電位觸點(diǎn),受控軟件 |
| 斷電容量 AC | 240 V AC, max 8 A, max load 2000 VA |
| 打破能力 DC | 275 V DC, max 8 A, max load 240 W |
| 低電平輸出(Rogowski option) | |
|
設(shè)定范圍 LLU LLI |
3 X 0...2 V RMS 3 X 0...2 V RMS |
| 最大輸出電流 | 5 mA |
| 不準(zhǔn)確的決議 | <0.1% typ. (<0.2% guaranteed) |
| 失真 (THD+N)2) Max. | 250 μV |
| 產(chǎn)生時(shí)間 |
<0.05% typ. (<0.1% guaranteed) 5 minutes |
| 發(fā)電機(jī)部分 | |
| 電壓輸出 | |
|
范圍 4- 相 AC 1- 相 AC (L-L) DC(L-N) |
4 x 150 V 2 x 300 V 180 V |
|
功率 3- 相 AC 1- 相 AC (L-L) DC(L-N) |
3 x 82 VA at 150 V 1 x 140 VA at 300 V 87 W |
|
分辨率 SW HW |
10 mV 6.5 mV |
| 不確定度 3) ( 保證 ) | (±0.01% of range) + (±0.05% of reading) |
| 失真 (THD+N)4) | 0.02% typical (0.04% max) |
| 電流輸出 | |
| 標(biāo)準(zhǔn)輸出 – L1I, L2I, L3I | |
|
范圍 3- 相 AC 1- 相 AC 2) DC(L-N) 3-通道DC |
3 x 15 A 1 x 45 A 15 A - |
|
功率 3- 相 AC 1- 相 AC 2) DC(L-N) |
3 x 87 VA 1 x 250 VA 3 x 87 W(max) |
|
分辨率 SW HW |
1 mA 0.65 mA |
| 不確定度 3) ( 保證 ) | (±0.01% of range) + (±0.3% of reading) |
| 失真 (THD+N)4) | 0.1% typical (0.2% max) |
| 中斷輸出 – Ch1, Ch2, Ch3 | |
| 電壓瞬變 - | 抗擾度 2500 V 瞬態(tài)水平(to chassis) +工作電壓等級(jí)(255 V) |
| 工作電壓 | 255 V |
| 應(yīng)用 | |
| 3- 相 AC( 每相 ) |
250 VA, 5 A < I ≤ 25 A 200 VA, 25 A < I ≤ 30 A 150 VA, 30 A < I ≤ 35 A |
| 1- 相 AC (3 ch. in parallel) |
750 VA, 15 A < I ≤ 75 A 600 VA, 75 A < I ≤ 90 A 450 VA, 90 A < I ≤ 100 A |
| 3-ch. DC 合規(guī)電 | 3 x ±20 A |
| 壓時(shí)間限制 | ≤50 Vrms |
| 連續(xù) | 3 x 20 A, 150 VA (max) |
| 0.5 秒在 1 秒內(nèi)反復(fù)熄滅 | 3 x 35 A |
| 分辨率 | 1.6 mA |
| 典型不確定度 |
< 0.3% (of reading), 0.5 A < I ≤ 35 A < 8 mA, 0 A < I ≤0.5 A |
| 相不確定度 | < ±0.2° |
| 失真 (THD+N) 6) | < 0.4% typical |
| 發(fā)電機(jī),一般 | |
| 頻率范圍 |
|
| 連續(xù)信號(hào) | DC – 2000 Hz |
| 瞬態(tài)信號(hào) | DC – 3.5 kHz |
| 頻率分辨率 | 1 mHz |
| 頻率不確定度 | 0.01% |
| 相角范圍 | 0 – 360° |
| 相位分辨率 | 0.1° |
| 相位不確定度 | ±0.1° |
| 連接(放大器輸出) | 4 mm可堆疊安全插頭或8針?lè)糯笃鞫喙δ懿蹇?/span> |
| 所有七臺(tái)發(fā)電機(jī)在振幅和相位上均可連續(xù)獨(dú)立調(diào)節(jié)。不需要切換范圍。 所有的電流和電壓輸出都是完全過(guò)載和短路保護(hù),可以防止外部高壓瞬態(tài)信號(hào)和過(guò)熱。 | |
| 注意 允許連續(xù)生成高直流電流(12-15 A),需要0.2歐姆的最小負(fù)載阻抗。 對(duì)于較低的負(fù)載阻抗,例如 短路時(shí)間限制在1分鐘。 | |
| 直流輔助電壓輸出 | |
| 范圍 | 20 – 210 V DC |
| 輸出功率 | 75 W at 210 V |
|
MEGGER FREJA 306繼電器測(cè)試系統(tǒng)說(shuō)明文檔 |
|
MEGGER FREJA306繼電器測(cè)試系統(tǒng)作為國(guó)際領(lǐng)先的電力檢測(cè)設(shè)備,完全符合IEC60255系列國(guó)際標(biāo)準(zhǔn)、GB/T 7261《繼電保護(hù)和安全自動(dòng)裝置基本試驗(yàn)方法》國(guó)家標(biāo)準(zhǔn)、DL/T 624《繼電保護(hù)微機(jī)型試驗(yàn)裝置技術(shù)條件》電力行業(yè)標(biāo)準(zhǔn),滿(mǎn)足國(guó)內(nèi)B端電力工程企業(yè)、G端電網(wǎng)單位的采購(gòu)合規(guī)要求。該設(shè)備配置6路獨(dú)立可并聯(lián)電流輸出通道,單路最大輸出電流30A,并聯(lián)后最大可達(dá)180A,4路獨(dú)立電壓輸出通道單路最高輸出300V,測(cè)量精度達(dá)0.05級(jí),幅值、相位分辨率分別可達(dá)0.001A/V、0.001°,可充分滿(mǎn)足各類(lèi)繼電保護(hù)裝置的高精度測(cè)試需求。其適用場(chǎng)景覆蓋10kV~1000kV全電壓等級(jí)變電站的運(yùn)維巡檢、新站投運(yùn)驗(yàn)收、繼電保護(hù)裝置定期校驗(yàn)、故障后二次回路排查等工作,同時(shí)可用于火電、水電、風(fēng)電、光伏等各類(lèi)發(fā)電場(chǎng)站的繼電保護(hù)檢測(cè),以及第三方電力檢測(cè)機(jī)構(gòu)的外業(yè)測(cè)試作業(yè),還支持二次回路絕緣性能初篩,為電力運(yùn)維人員降低現(xiàn)場(chǎng)作業(yè)風(fēng)險(xiǎn),提升檢測(cè)效率,目前已成為國(guó)內(nèi)多數(shù)省級(jí)電網(wǎng)公司、大型發(fā)電集團(tuán)、電力工程承建商的繼電保護(hù)測(cè)試標(biāo)配設(shè)備。
MEGGER FREJA306繼電器測(cè)試系統(tǒng)針對(duì)各類(lèi)復(fù)雜電力檢測(cè)場(chǎng)景做了專(zhuān)項(xiàng)優(yōu)化,完全可以滿(mǎn)足不同環(huán)境、不同類(lèi)型的特殊測(cè)試需求:環(huán)境適應(yīng)性上,設(shè)備通過(guò)了GB/T 2423系列高低溫、濕熱、振動(dòng)沖擊測(cè)試,防護(hù)等級(jí)達(dá)IP20,除了常規(guī)室內(nèi)實(shí)驗(yàn)室測(cè)試外,還可直接在戶(hù)外變電站、高海拔山區(qū)變電站、沿海高鹽霧區(qū)域變電站、戈壁荒漠區(qū)域變電站等復(fù)雜環(huán)境下穩(wěn)定運(yùn)行,不會(huì)因?yàn)闇貪穸取⒑0巍h(huán)境腐蝕等問(wèn)題出現(xiàn)測(cè)量偏差。特殊檢測(cè)項(xiàng)目上,除了常規(guī)繼電保護(hù)測(cè)試外,設(shè)備還支持二次回路絕緣電阻測(cè)試,可直接完成二次回路的絕緣性能排查,無(wú)需額外攜帶絕緣檢測(cè)設(shè)備;支持暫態(tài)故障模擬測(cè)試,可模擬各類(lèi)短路故障、電壓暫降、暫態(tài)過(guò)電壓等復(fù)雜電網(wǎng)工況,完成繼電保護(hù)裝置的暫態(tài)動(dòng)作性能校驗(yàn);支持新能源場(chǎng)站的特殊繼電保護(hù)測(cè)試,包括風(fēng)電、光伏場(chǎng)站的箱變保護(hù)裝置測(cè)試、防孤島保護(hù)裝置測(cè)試、低電壓穿越能力測(cè)試等,適配新型電力系統(tǒng)的檢測(cè)需求;同時(shí)支持自定義故障波形導(dǎo)入,可將歷史故障錄波文件導(dǎo)入設(shè)備復(fù)現(xiàn)故障場(chǎng)景,完成繼電保護(hù)裝置的動(dòng)作邏輯校驗(yàn),充分滿(mǎn)足各類(lèi)特殊電力測(cè)試需求。
MEGGER FREJA306繼電器測(cè)試系統(tǒng)完全適配國(guó)內(nèi)電力行業(yè)的數(shù)字化運(yùn)維要求,支持多類(lèi)主流通訊協(xié)議:常規(guī)工業(yè)協(xié)議支持Modbus-RTU、Modbus-TCP,智能變電站協(xié)議支持IEC61850 MMS、IEC61850 GOOSE、IEC61850 SV,可直接對(duì)接各類(lèi)智能繼電保護(hù)裝置、合并單元、智能終端等設(shè)備。設(shè)備配置USB3.0、千兆以太網(wǎng)、WIFI三類(lèi)數(shù)據(jù)接口,支持直接對(duì)接電力企業(yè)現(xiàn)有運(yùn)維巡檢系統(tǒng)、變電站在線(xiàn)監(jiān)測(cè)系統(tǒng)、電力檢測(cè)數(shù)據(jù)管理平臺(tái),測(cè)試過(guò)程中可實(shí)時(shí)上傳測(cè)試數(shù)據(jù)、波形文件、測(cè)試結(jié)果,無(wú)需人工手動(dòng)錄入,避免數(shù)據(jù)錯(cuò)漏,同時(shí)可自動(dòng)匹配電力行業(yè)要求的測(cè)試報(bào)告模板,生成符合DL/T規(guī)范的標(biāo)準(zhǔn)化測(cè)試報(bào)告,同步歸檔到對(duì)應(yīng)系統(tǒng)中。此外該設(shè)備可兼容國(guó)內(nèi)主流品牌的繼電保護(hù)裝置,包括南瑞、許繼、四方、南自等品牌的各型號(hào)保護(hù)裝置,無(wú)需額外配置適配插件,即可完成全流程檢測(cè)測(cè)試,充分滿(mǎn)足G端電網(wǎng)單位的數(shù)字化運(yùn)維升級(jí)要求,也可降低B端電力檢測(cè)企業(yè)的系統(tǒng)改造成本,提升整體作業(yè)效率。
MEGGER FREJA306繼電器測(cè)試系統(tǒng)的核心技術(shù)參數(shù)完全適配國(guó)內(nèi)電力測(cè)試的各類(lèi)要求:輸出頻率范圍覆蓋0~1000Hz,支持最多16次諧波疊加,可模擬各類(lèi)復(fù)雜電網(wǎng)波形;內(nèi)置高精度測(cè)量模塊,電流測(cè)量范圍0~180A,電壓測(cè)量范圍0~1200V,絕緣電阻測(cè)試量程覆蓋0~10GΩ,所有測(cè)量項(xiàng)精度均優(yōu)于行業(yè)標(biāo)準(zhǔn)要求。該設(shè)備可覆蓋95%以上的繼電保護(hù)測(cè)試需求:常規(guī)測(cè)試項(xiàng)目包含過(guò)流保護(hù)、過(guò)壓保護(hù)、欠壓保護(hù)、差動(dòng)保護(hù)、距離保護(hù)、零序保護(hù)、備自投裝置測(cè)試、重合閘裝置測(cè)試等;特殊測(cè)試項(xiàng)目包含CT/PT變比極性測(cè)試、二次回路絕緣檢測(cè)、故障錄波裝置校驗(yàn)、智能站GOOSE報(bào)文仿真測(cè)試等。既可以滿(mǎn)足電網(wǎng)運(yùn)維部門(mén)日常變電站巡檢的常規(guī)校驗(yàn)需求,也可以滿(mǎn)足電力科研院所的繼電保護(hù)性能試驗(yàn)需求,還可以滿(mǎn)足電力工程單位新站建設(shè)的繼電保護(hù)裝置調(diào)試驗(yàn)收需求,針對(duì)不同用戶(hù)的測(cè)試場(chǎng)景,設(shè)備還支持自定義測(cè)試流程編輯,可靈活適配各類(lèi)非標(biāo)測(cè)試需求。
面向變電站巡檢運(yùn)維場(chǎng)景采購(gòu)MEGGER FREJA306繼電器測(cè)試系統(tǒng)的核心優(yōu)勢(shì)主要體現(xiàn)在品牌、性能、易用性三個(gè)層面:品牌層面,MEGGER是擁有百年歷史的全球知名電力測(cè)試設(shè)備品牌,F(xiàn)REJA系列繼電器測(cè)試系統(tǒng)在全球電力行業(yè)的市場(chǎng)占有率超過(guò)30%,國(guó)內(nèi)省級(jí)電網(wǎng)單位的覆蓋率超過(guò)80%,產(chǎn)品性能經(jīng)過(guò)數(shù)十年市場(chǎng)驗(yàn)證,完全符合電力采購(gòu)的品質(zhì)要求。性能層面,該設(shè)備為便攜式設(shè)計(jì),整機(jī)重量?jī)H12kg,支持外接移動(dòng)電源供電,非常適合戶(hù)外變電站巡檢的外業(yè)作業(yè)需求,設(shè)備工作溫度范圍覆蓋-20℃~55℃,海拔5000米以下可正常運(yùn)行,適配高原、高寒、高溫等各類(lèi)特殊環(huán)境的變電站運(yùn)維作業(yè),測(cè)試精度長(zhǎng)期穩(wěn)定性?xún)?yōu)于同類(lèi)產(chǎn)品30%以上,無(wú)需頻繁校準(zhǔn)。易用性層面,設(shè)備內(nèi)置超過(guò)1000種預(yù)置測(cè)試模板,覆蓋國(guó)內(nèi)90%以上的常用繼電保護(hù)測(cè)試場(chǎng)景,無(wú)需運(yùn)維人員手動(dòng)編輯測(cè)試流程,選擇對(duì)應(yīng)模板即可一鍵啟動(dòng)測(cè)試,測(cè)試效率相比同類(lèi)設(shè)備提升40%以上,可大幅縮短變電站巡檢的停電作業(yè)時(shí)間,降低電力系統(tǒng)運(yùn)行風(fēng)險(xiǎn),是電網(wǎng)運(yùn)維部門(mén)、第三方電力檢測(cè)機(jī)構(gòu)的首選設(shè)備。