FREJA300繼電保護(hù)測(cè)試儀訂購(gòu)信息 |
|
| Description | Style Number |
|
FREJA 300 Standalone: Includes: International power cord, IEC 61850 test capability,
Transducer test capability, and test leads.
|
F300-30P2C1I1T1 |
|
FREJA 300 Standalone: Includes: International power cord, with IEC 61850 test capability,
and test leads. Excludes: No transducer test capability
|
F300-30P2C1I1S1 |
|
FREJA 300 Standalone: Includes: International power cord, Transducer test capability,
and test leads. Excludes: no IEC 61850 test capability
|
F300-30P2C1I0T1 |
|
FREJA 300 Standalone: Includes: International power cord, and test leads. Excludes: no IEC
61850 test capability, no transducer test capability
|
F300-30P2C1I0S1 |
|
FREJA 300 Standalone: Includes: International power cord and Transducer test capability.
Excludes: no IEC 61850 test capability, no test leads
|
F300-30P2C1I0T0 |
|
FREJA 300 Standalone: Includes: International power cord, with IEC 61850 test capability.
Excludes: No transducer test capability, no test leads
|
F300-30P2C1I1S0 |
|
FREJA 300 Standalone: Includes: International power cord. Excludes: no IEC 61850 test
capability, no transducer test capability, no test leads
|
F300-30P2C1I0S0 |
|
Included Software – Every unit comes with the PC version of the
FREJA Local software called FREJA Remote.
|
84835 |
| Optional Software | 84673 |
| FREJA Win |
|
| Included Standard Accessories |
|
| Power Cord - Depending on the style number, the unit will come with one of the following, |
|
| Line cord, NEMA | 90015-267 |
| Line cord, Continental Europe with CEE 7/7 Schuko Plug | 90015-268 |
| Line cord, International color coded wire | 90015-269 |
| Line cord, United Kingdom | 90015-270 |
| Ethernet cable for interconnection to PC, 210cm (7 ft.) long (Qty. 1 ea.) | 90003-594 |
| Instruction manual (digital copy) | 84624 |
|
|
|
|
FREJA300繼電保護(hù)測(cè)試儀規(guī)格 |
||
| 輸出 | ||
| 項(xiàng)目 | 電壓輸出 | 電流輸出 |
| 范圍 | 4 相AC?? 4× 150V | 3 相AC?? 3× 15V |
| 1 相AC(L-L) 2 ×300V | 1 相AC?? 1× 45V | |
| DC(L-N) 180V | DC(L-N) 15V | |
| 功率 | 3 相AC (L-L) 3× 82VA, 150V | 3 相AC?? 3× 87VA |
| 1 相AC1 1×140VA,300V | 1 相AC?? 1× 150VA | |
| DC(L-N) 87W | DC(L-N) 3 ×87W | |
| 分辨率 | SW 10mv | SW 10mA |
| HW 6.5mv | HW 0.65mv | |
| 精度 | ± 0.01%的范圍+0.09% 的讀數(shù) | ± 0.01%的范圍+0.03% 的讀數(shù) |
| 其他參數(shù) | ||
| 頻率范圍連續(xù)信號(hào) | DC-2000HZ | |
| 頻率范圍暫態(tài)信號(hào) | DC-3.5KHZ | |
| 頻率分辨率 | 1mHz | |
| 頻率精度 | 0.01% | |
| 相角范圍 | 0-360度 | |
| 相角分辨率 | 0.1度 | |
| 相角精度 | ±0. 1度 | |
| AC/DC電流電壓測(cè)量功能 | ||
| 時(shí)間點(diǎn)數(shù) |
10V?275Vdc 240Vac |
|
| 分辨率 | 50S | |
| 電隔離 | 與放大器部分電氣上隔離兩組電氣隔離單元1到5和6到10 | |
| 最大測(cè)量時(shí)間性 | 15264h(636天) | |
| 范圍分辨率 |
0-9.9mS 0.1mS 10mS-60min 1 mS 1h-15264h |
|
| 體 積 | 510×390×120mm | |
| 重量 | 15kg | |
|
MEGGER FREJA300繼電保護(hù)測(cè)試系統(tǒng)說(shuō)明文檔 |
||
MEGGER FREJA300繼電保護(hù)測(cè)試儀內(nèi)置LOCAL本地獨(dú)立操作、PC端遠(yuǎn)程操作兩大操作模式,可適配不同使用場(chǎng)景的測(cè)試需求。LOCAL本地獨(dú)立操作模式下,用戶(hù)無(wú)需連接PC端,僅通過(guò)設(shè)備本身的操作界面即可完成全部測(cè)試操作,每一項(xiàng)功能鍵對(duì)應(yīng)的操作說(shuō)明、參數(shù)設(shè)置選項(xiàng)、實(shí)時(shí)測(cè)試數(shù)值均可在設(shè)備顯示屏上直接查看,操作邏輯簡(jiǎn)單易上手,該模式特別適配戶(hù)外現(xiàn)場(chǎng)測(cè)試場(chǎng)景,尤其是無(wú)外接電源、無(wú)PC支持的野外變電站、偏遠(yuǎn)路段供電設(shè)施的臨時(shí)測(cè)試、故障排查場(chǎng)景,搭配設(shè)備僅15kg的輕量化便攜設(shè)計(jì)、寬溫度環(huán)境適應(yīng)能力,可大幅提升現(xiàn)場(chǎng)測(cè)試效率。PC端遠(yuǎn)程操作模式下,用戶(hù)可通過(guò)標(biāo)配的FREJA Remote軟件實(shí)現(xiàn)設(shè)備的遠(yuǎn)程控制,軟件提供可視化操作界面,支持測(cè)試流程自定義設(shè)置、測(cè)試數(shù)據(jù)自動(dòng)存儲(chǔ)與分析、復(fù)雜故障工況仿真模擬等功能,該模式適配室內(nèi)實(shí)驗(yàn)室的批量繼電保護(hù)裝置校準(zhǔn)、新型保護(hù)裝置性能研發(fā)測(cè)試、復(fù)雜故障邏輯驗(yàn)證等場(chǎng)景,同時(shí)支持自動(dòng)與手動(dòng)控制切換,既可以設(shè)置全自動(dòng)測(cè)試流程完成批量設(shè)備的標(biāo)準(zhǔn)化校驗(yàn),也可以切換手動(dòng)模式完成自定義工況的測(cè)試需求。兩種操作模式可根據(jù)使用場(chǎng)景靈活切換,可覆蓋從日常巡檢、故障排查到實(shí)驗(yàn)室檢定
MEGGER FREJA300繼電保護(hù)測(cè)試儀的通道配置采用了獨(dú)立式設(shè)計(jì),每個(gè)電壓輸出通道、電流輸出通道均為獨(dú)立架構(gòu),不同通道之間不會(huì)產(chǎn)生信號(hào)干擾,可有效保障測(cè)試數(shù)據(jù)的準(zhǔn)確性,同時(shí)支持多通道同步輸出,可模擬各類(lèi)復(fù)雜的電氣運(yùn)行場(chǎng)景,滿(mǎn)足差動(dòng)保護(hù)、距離保護(hù)等復(fù)雜繼電保護(hù)設(shè)備的測(cè)試需求。除了常規(guī)的電壓、電流輸出通道外,該設(shè)備還配備了兩類(lèi)專(zhuān)屬輸入通道:一類(lèi)是低位準(zhǔn)模擬輸入通道,專(zhuān)門(mén)針對(duì)傳送器、變送器類(lèi)設(shè)備的測(cè)試需求設(shè)計(jì),可精準(zhǔn)采集傳送器輸出的低幅值模擬信號(hào),完成傳送器的精度校驗(yàn)、線(xiàn)性度測(cè)試、響應(yīng)時(shí)間測(cè)試等項(xiàng)目;另一類(lèi)是高位準(zhǔn)輸入通道,專(zhuān)門(mén)針對(duì)瓦時(shí)計(jì)等電能計(jì)量設(shè)備的測(cè)試需求設(shè)計(jì),可承受高幅值的輸入信號(hào),完成瓦時(shí)計(jì)的誤差測(cè)試、功能核驗(yàn)、一致性測(cè)試等項(xiàng)目。該通道配置可充分滿(mǎn)足多場(chǎng)景的測(cè)試需求:在電力行業(yè)變電站檢測(cè)場(chǎng)景中,可同時(shí)完成多組繼電保護(hù)設(shè)備的定值校驗(yàn),無(wú)需重復(fù)接線(xiàn);在工業(yè)廠區(qū)檢測(cè)場(chǎng)景中,可一次性完成繼電保護(hù)設(shè)備校驗(yàn)、生產(chǎn)線(xiàn)上傳送器校準(zhǔn)、電能計(jì)量設(shè)備測(cè)試等多類(lèi)檢測(cè)項(xiàng)目,無(wú)需更換設(shè)備;在戶(hù)外運(yùn)維巡檢場(chǎng)景中,單臺(tái)設(shè)備即可覆蓋故障排查、絕緣測(cè)試配套電氣參數(shù)校驗(yàn)、輻射監(jiān)測(cè)配套電氣檢測(cè)等多類(lèi)需求,大幅降低現(xiàn)
MEGGER FREJA300繼電保護(hù)測(cè)試儀作為工業(yè)級(jí)高精度檢測(cè)設(shè)備,嚴(yán)格符合IEC國(guó)際電工委員會(huì)繼電保護(hù)測(cè)試相關(guān)標(biāo)準(zhǔn)、GB/T繼電保護(hù)裝置通用技術(shù)條件國(guó)家標(biāo)準(zhǔn)、DL/T電力行業(yè)繼電保護(hù)測(cè)試相關(guān)規(guī)范,同時(shí)適配核工業(yè)、軌道交通、水務(wù)環(huán)保等領(lǐng)域的專(zhuān)項(xiàng)檢測(cè)技術(shù)要求,可滿(mǎn)足各類(lèi)國(guó)有單位、政府類(lèi)檢測(cè)項(xiàng)目的標(biāo)準(zhǔn)合規(guī)性要求。該設(shè)備可適配的G端用戶(hù)檢測(cè)需求包括:電網(wǎng)公司類(lèi)單位的主網(wǎng)、配網(wǎng)繼電保護(hù)設(shè)備定期校驗(yàn)項(xiàng)目、新入網(wǎng)繼電保護(hù)設(shè)備參數(shù)核驗(yàn)項(xiàng)目、輸電線(xiàn)路故障排查專(zhuān)項(xiàng)檢測(cè)項(xiàng)目;核工業(yè)相關(guān)國(guó)有單位的核電廠電氣系統(tǒng)安全檢測(cè)項(xiàng)目、輻射監(jiān)測(cè)配套電氣參數(shù)校驗(yàn)項(xiàng)目;軌道交通運(yùn)營(yíng)類(lèi)國(guó)有單位的城市軌道交通牽引供電系統(tǒng)繼電保護(hù)設(shè)備測(cè)試項(xiàng)目、高鐵供電線(xiàn)路運(yùn)維巡檢項(xiàng)目;水務(wù)、環(huán)保類(lèi)政府單位的城鄉(xiāng)供水系統(tǒng)電氣設(shè)備安全檢測(cè)項(xiàng)目、環(huán)保整治項(xiàng)目涉電環(huán)節(jié)的環(huán)境評(píng)估項(xiàng)目、公共區(qū)域電氣設(shè)備絕緣測(cè)試項(xiàng)目等。設(shè)備支持的全類(lèi)型繼電保護(hù)二次測(cè)試、故障模擬與預(yù)判、傳送器與瓦時(shí)計(jì)測(cè)試等功能,均可覆蓋上述單位的常規(guī)檢測(cè)與專(zhuān)項(xiàng)檢測(cè)需求,同時(shí)測(cè)試數(shù)據(jù)精度滿(mǎn)足各類(lèi)標(biāo)準(zhǔn)要求,可作為項(xiàng)目合規(guī)性核驗(yàn)的有效技術(shù)依據(jù)。
MEGGER FREJA300繼電保護(hù)測(cè)試儀是美國(guó)Megger推出的高精度工業(yè)檢測(cè)設(shè)備,屬于計(jì)算機(jī)輔助的繼電器測(cè)試及仿真系統(tǒng),核心定位是滿(mǎn)足各類(lèi)工業(yè)場(chǎng)景下的繼電保護(hù)設(shè)備檢測(cè)需求。該設(shè)備的核心功能覆蓋多類(lèi)檢測(cè)場(chǎng)景:首先支持全類(lèi)型繼電保護(hù)設(shè)備的二次測(cè)試,基本可覆蓋市面上所有繼電保護(hù)設(shè)備的校驗(yàn)需求;其次同時(shí)支持靜態(tài)測(cè)試與動(dòng)態(tài)測(cè)試,可完成故障模擬測(cè)試、故障預(yù)判等進(jìn)階檢測(cè)需求,適配運(yùn)維巡檢、故障排查等多個(gè)工作環(huán)節(jié);另外配備專(zhuān)屬的低位準(zhǔn)模擬輸入功能,專(zhuān)門(mén)用于傳送器測(cè)試場(chǎng)景,高位準(zhǔn)輸入通道可支持瓦時(shí)計(jì)測(cè)試需求,單臺(tái)設(shè)備即可覆蓋多類(lèi)電氣參數(shù)檢測(cè)需求。設(shè)備還支持自動(dòng)與手動(dòng)兩種控制模式,用戶(hù)可根據(jù)測(cè)試需求靈活切換,同時(shí)支持LOCAL獨(dú)立操作模式,無(wú)需外接計(jì)算機(jī)即可在現(xiàn)場(chǎng)完成全流程測(cè)試,顯示屏可實(shí)時(shí)展示每一項(xiàng)功能的描述、參數(shù)設(shè)置情況與實(shí)時(shí)測(cè)試值,降低現(xiàn)場(chǎng)操作難度。該設(shè)備重量?jī)H15kg,搭配堅(jiān)固的外殼設(shè)計(jì),可適配不同溫度環(huán)境下的現(xiàn)場(chǎng)使用需求,不管是常規(guī)工業(yè)廠區(qū)的日常檢測(cè),還是戶(hù)外復(fù)雜環(huán)境下的專(zhuān)項(xiàng)檢測(cè)項(xiàng)目都可穩(wěn)定運(yùn)行,廣泛應(yīng)用于運(yùn)維巡檢、故障檢測(cè)、絕緣測(cè)試、輻射監(jiān)測(cè)、環(huán)境評(píng)估等多個(gè)工業(yè)檢測(cè)領(lǐng)域。
使用MEGGER FREJA300繼電保護(hù)測(cè)試儀可從多個(gè)維度提升工業(yè)檢測(cè)項(xiàng)目的運(yùn)行效率,幫助企業(yè)用戶(hù)實(shí)現(xiàn)更高的投入產(chǎn)出比。首先是設(shè)備便攜性帶來(lái)的現(xiàn)場(chǎng)效率提升:該設(shè)備重量?jī)H15kg,搭配堅(jiān)固外殼,可適配不同溫度的現(xiàn)場(chǎng)環(huán)境,運(yùn)輸與攜帶難度低,無(wú)需復(fù)雜的搬運(yùn)設(shè)備即可帶到各類(lèi)戶(hù)外、高空、偏遠(yuǎn)區(qū)域的檢測(cè)現(xiàn)場(chǎng),大幅減少檢測(cè)前的設(shè)備準(zhǔn)備時(shí)間。其次是功能集成性帶來(lái)的流程效率提升:?jiǎn)闻_(tái)設(shè)備集成了繼電保護(hù)二次測(cè)試、故障模擬與預(yù)判、傳送器測(cè)試、瓦時(shí)計(jì)測(cè)試等多類(lèi)檢測(cè)功能,同時(shí)支持靜態(tài)、動(dòng)態(tài)兩種測(cè)試模式,可覆蓋運(yùn)維巡檢、故障檢測(cè)、絕緣測(cè)試、輻射監(jiān)測(cè)、環(huán)境評(píng)估等多類(lèi)檢測(cè)場(chǎng)景的需求,無(wú)需攜帶多臺(tái)不同功能的檢測(cè)設(shè)備,也無(wú)需在不同檢測(cè)項(xiàng)目之間反復(fù)更換設(shè)備、調(diào)整接線(xiàn),可減少50%以上的現(xiàn)場(chǎng)操作流程耗時(shí)。另外是操作便捷性帶來(lái)的測(cè)試效率提升:設(shè)備支持LOCAL本地獨(dú)立操作與智能軟件控制兩種模式,本地操作模式下無(wú)需外接計(jì)算機(jī),顯示屏可直觀展示功能說(shuō)明、參數(shù)設(shè)置與測(cè)試數(shù)值,操作門(mén)檻低;智能軟件模式下可實(shí)現(xiàn)批量測(cè)試、自動(dòng)生成測(cè)試邏輯,無(wú)需人工反復(fù)調(diào)整參數(shù),可大幅提升批量檢測(cè)項(xiàng)目的測(cè)試效率。對(duì)于電力、軌道交通等需要開(kāi)展大規(guī)模定期檢測(cè)
MEGGER FREJA300繼電保護(hù)測(cè)試儀的應(yīng)用場(chǎng)景覆蓋電力、核工業(yè)、軌道交通、工礦企業(yè)、科研教學(xué)等多個(gè)領(lǐng)域,適配現(xiàn)場(chǎng)作業(yè)與實(shí)驗(yàn)室測(cè)試兩類(lèi)需求。在電力行業(yè),可應(yīng)用于電網(wǎng)企業(yè)各級(jí)變電站的繼電保護(hù)裝置定期校驗(yàn)、新建變電站的交接試驗(yàn)、特高壓工程的保護(hù)裝置現(xiàn)場(chǎng)調(diào)試,也可應(yīng)用于火電、水電、光伏、風(fēng)電等各類(lèi)發(fā)電企業(yè)的廠站繼電保護(hù)系統(tǒng)定檢,是供配電系統(tǒng)運(yùn)維、基建環(huán)節(jié)的核心測(cè)試設(shè)備。在核工業(yè)領(lǐng)域,可用于核電廠常規(guī)島、核島配套繼電保護(hù)裝置的校驗(yàn)測(cè)試,滿(mǎn)足核電系統(tǒng)高可靠性的測(cè)試要求。在軌道交通領(lǐng)域,可用于高鐵、地鐵線(xiàn)路的牽引供電系統(tǒng)繼電保護(hù)裝置、同相供電裝置的測(cè)試校驗(yàn),保障軌道交通供電系統(tǒng)的穩(wěn)定運(yùn)行。在工礦企業(yè)場(chǎng)景,可用于石化、冶金、煤炭等大型工礦企業(yè)的內(nèi)部供配電系統(tǒng)保護(hù)裝置測(cè)試,降低企業(yè)供配電系統(tǒng)的故障風(fēng)險(xiǎn)。同時(shí)該設(shè)備也適用于電力科研院所的繼電保護(hù)裝置研發(fā)測(cè)試、高校電氣專(zhuān)業(yè)的繼電保護(hù)課程實(shí)驗(yàn)等實(shí)驗(yàn)室場(chǎng)景。由于設(shè)備支持寬溫現(xiàn)場(chǎng)作業(yè),不管是北方低溫環(huán)境下的戶(hù)外變電站、南方高溫高濕區(qū)域的沿海站點(diǎn),還是高原低氣壓環(huán)境的新能源電站,都可正常開(kāi)展測(cè)試工作,無(wú)需調(diào)整測(cè)試流程,大幅提升不同場(chǎng)景下的測(cè)試效率。
MEGGER FREJA300繼電保護(hù)測(cè)試儀完全支持現(xiàn)場(chǎng)獨(dú)立操作,無(wú)需外接計(jì)算機(jī)即可完成全流程測(cè)試,適配戶(hù)外現(xiàn)場(chǎng)、無(wú)外接計(jì)算設(shè)備條件下的檢測(cè)需求。其獨(dú)立操作流程非常簡(jiǎn)便:首先將設(shè)備開(kāi)機(jī)后,通過(guò)面板按鍵選擇進(jìn)入LOCAL本地操作模式,進(jìn)入該模式后,設(shè)備顯示屏?xí)?duì)每一項(xiàng)功能鍵的作用進(jìn)行直觀展示,用戶(hù)可根據(jù)檢測(cè)需求選擇對(duì)應(yīng)的測(cè)試項(xiàng)目,比如繼電保護(hù)定值校驗(yàn)、傳送器測(cè)試、瓦時(shí)計(jì)測(cè)試、故障模擬測(cè)試等;選定測(cè)試項(xiàng)目后,根據(jù)顯示屏提示完成測(cè)試參數(shù)設(shè)置,設(shè)置過(guò)程中顯示屏?xí)?shí)時(shí)展示當(dāng)前設(shè)置的參數(shù)數(shù)值,避免設(shè)置錯(cuò)誤;參數(shù)設(shè)置完成后,按照接線(xiàn)規(guī)范將設(shè)備的電壓、電流通道與待測(cè)設(shè)備完成接線(xiàn),確認(rèn)接線(xiàn)無(wú)誤后即可啟動(dòng)測(cè)試;測(cè)試過(guò)程中顯示屏?xí)?shí)時(shí)展示當(dāng)前的測(cè)試數(shù)值、測(cè)試進(jìn)度,測(cè)試完成后會(huì)自動(dòng)存儲(chǔ)測(cè)試結(jié)果,用戶(hù)可直接在設(shè)備上查看測(cè)試數(shù)據(jù),也可后續(xù)導(dǎo)出數(shù)據(jù)用于歸檔。除了本地獨(dú)立操作模式外,該設(shè)備也支持外接計(jì)算機(jī)通過(guò)配套智能軟件進(jìn)行控制,軟件具備清晰的視覺(jué)交互界面,參數(shù)設(shè)置流程簡(jiǎn)單,可實(shí)現(xiàn)批量測(cè)試、復(fù)雜故障場(chǎng)景仿真等進(jìn)階操作需求,用戶(hù)可根據(jù)現(xiàn)場(chǎng)條件與測(cè)試需求靈活選擇操作模式。設(shè)備僅重15kg,便攜性強(qiáng),搭配堅(jiān)固外殼,可適應(yīng)不
MEGGER FREJA300繼電保護(hù)測(cè)試儀采用了堅(jiān)固的外殼設(shè)計(jì)與寬溫適配的硬件配置,可適配各類(lèi)惡劣環(huán)境下的現(xiàn)場(chǎng)檢測(cè)需求。首先是溫度適配范圍廣,可在高溫、低溫等極端溫度環(huán)境下穩(wěn)定運(yùn)行,可滿(mǎn)足北方高寒地區(qū)冬季戶(hù)外變電站檢測(cè)、南方高溫高濕環(huán)境下工業(yè)廠區(qū)電氣檢測(cè)、戈壁荒漠等極端溫度區(qū)域的輸電線(xiàn)路運(yùn)維巡檢等場(chǎng)景的需求。其次是便攜性強(qiáng),僅15kg的重量搭配堅(jiān)固的防摔外殼,可適配高空作業(yè)、山區(qū)巡檢、偏遠(yuǎn)無(wú)道路區(qū)域的檢測(cè)需求,無(wú)需復(fù)雜的搬運(yùn)設(shè)備即可由單人攜帶到達(dá)檢測(cè)現(xiàn)場(chǎng),適配軌道交通接觸網(wǎng)高空檢測(cè)、山區(qū)輸電線(xiàn)路故障排查、偏遠(yuǎn)地區(qū)水務(wù)站電氣檢測(cè)等場(chǎng)景的需求。另外該設(shè)備支持LOCAL本地獨(dú)立操作模式,無(wú)需外接計(jì)算機(jī),也無(wú)需穩(wěn)定的外接網(wǎng)絡(luò)支持,即可完成全流程測(cè)試,可適配無(wú)網(wǎng)絡(luò)覆蓋的偏遠(yuǎn)區(qū)域、核電廠輻射監(jiān)測(cè)區(qū)域等無(wú)法使用外接計(jì)算設(shè)備的場(chǎng)景需求,同時(shí)設(shè)備的抗干擾設(shè)計(jì)可保障在強(qiáng)電磁干擾的場(chǎng)景下穩(wěn)定運(yùn)行,比如變電站高壓區(qū)域、工業(yè)生產(chǎn)強(qiáng)電磁環(huán)境下的檢測(cè)場(chǎng)景,仍可保持測(cè)試數(shù)據(jù)的準(zhǔn)確性。該設(shè)備的環(huán)境適配能力可覆蓋運(yùn)維巡檢、故障檢測(cè)、絕緣測(cè)試、輻射監(jiān)測(cè)、環(huán)境評(píng)估等各類(lèi)工業(yè)檢測(cè)場(chǎng)景的現(xiàn)場(chǎng)需求,無(wú)需額外的環(huán)境防護(hù)設(shè)備即可正常
MEGGER FREJA300繼電保護(hù)測(cè)試儀的核心技術(shù)參數(shù)與配置可滿(mǎn)足多場(chǎng)景高精度檢測(cè)需求:機(jī)身重量?jī)H15kg,采用高強(qiáng)度堅(jiān)固外殼設(shè)計(jì),工作溫度覆蓋范圍廣,可適配不同溫度條件下的現(xiàn)場(chǎng)使用需求;通道配置方面,每個(gè)電壓通道與電流通道均為獨(dú)立設(shè)計(jì),可避免不同信號(hào)之間的干擾,保障測(cè)試精度,同時(shí)配備專(zhuān)屬低位準(zhǔn)模擬輸入通道與高位準(zhǔn)輸入通道,分別適配傳送器測(cè)試與瓦時(shí)計(jì)測(cè)試需求;操作模式方面,支持外接計(jì)算機(jī)的智能軟件控制模式與LOCAL獨(dú)立操作模式,智能軟件具備清晰的視覺(jué)交互效果,參數(shù)設(shè)置流程簡(jiǎn)單,LOCAL模式下無(wú)需外接設(shè)備即可獨(dú)立完成測(cè)試,顯示屏可實(shí)時(shí)展示功能說(shuō)明、設(shè)置參數(shù)與測(cè)試數(shù)值。該設(shè)備的適用場(chǎng)景覆蓋通用工業(yè)領(lǐng)域的各類(lèi)檢測(cè)需求:在電力行業(yè)可用于變電站繼電保護(hù)設(shè)備定期校驗(yàn)、輸電線(xiàn)路故障排查、配網(wǎng)運(yùn)維巡檢等場(chǎng)景;在核工業(yè)領(lǐng)域可用于核電廠電氣系統(tǒng)繼電保護(hù)設(shè)備檢測(cè)、輻射監(jiān)測(cè)配套電氣參數(shù)校驗(yàn)等場(chǎng)景;在軌道交通行業(yè)可用于牽引供電系統(tǒng)繼電保護(hù)設(shè)備測(cè)試、接觸網(wǎng)故障預(yù)判等場(chǎng)景;在水務(wù)、環(huán)保行業(yè)可用于污水處理廠、供水系統(tǒng)的電氣設(shè)備絕緣測(cè)試、環(huán)保項(xiàng)目涉電環(huán)節(jié)的環(huán)境評(píng)估等場(chǎng)景,單臺(tái)設(shè)備即可覆蓋多類(lèi)檢測(cè)需求,降低現(xiàn)場(chǎng)檢
MEGGER FREJA300繼電保護(hù)測(cè)試儀作為專(zhuān)業(yè)的繼電保護(hù)測(cè)試系統(tǒng),可覆蓋市面上絕大多數(shù)類(lèi)型的繼電保護(hù)設(shè)備二次測(cè)試需求,具體包括電流繼電器、電壓繼電器、時(shí)間繼電器、中間繼電器、信號(hào)繼電器、差動(dòng)繼電器、距離繼電器、零序繼電器等常規(guī)繼電保護(hù)設(shè)備的定值校驗(yàn)、動(dòng)作特性測(cè)試、返回系數(shù)測(cè)試等基礎(chǔ)檢測(cè)項(xiàng)目,同時(shí)可適配微機(jī)保護(hù)裝置、智能變電站繼電保護(hù)裝置等新型繼電保護(hù)設(shè)備的全功能測(cè)試需求。除了常規(guī)繼電保護(hù)設(shè)備測(cè)試外,該設(shè)備還可覆蓋多類(lèi)關(guān)聯(lián)電氣設(shè)備的檢測(cè)需求:配備的低位準(zhǔn)模擬輸入功能可完成各類(lèi)工業(yè)變送器、傳送器的輸出精度校驗(yàn)、線(xiàn)性度測(cè)試等項(xiàng)目;高位準(zhǔn)輸入通道可支持各類(lèi)三相、單相瓦時(shí)計(jì)的誤差測(cè)試、功能核驗(yàn)等電能計(jì)量類(lèi)檢測(cè)項(xiàng)目;同時(shí)支持靜態(tài)測(cè)試與動(dòng)態(tài)測(cè)試兩種模式,靜態(tài)測(cè)試模式下可完成各類(lèi)設(shè)備的定值核驗(yàn)、常規(guī)性能檢測(cè),動(dòng)態(tài)測(cè)試模式下可模擬各類(lèi)真實(shí)故障場(chǎng)景,完成故障重現(xiàn)、故障預(yù)判、保護(hù)動(dòng)作邏輯驗(yàn)證等進(jìn)階檢測(cè)項(xiàng)目,可適配故障排查、新設(shè)備投運(yùn)核驗(yàn)、運(yùn)維巡檢等多類(lèi)工作場(chǎng)景的需求。不管是電力、核工業(yè)、軌道交通等對(duì)檢測(cè)精度要求較高的行業(yè),還是水務(wù)、環(huán)保、通用制造等常規(guī)工業(yè)領(lǐng)域,該設(shè)備均可滿(mǎn)足其繼電保護(hù)及關(guān)聯(lián)電氣設(shè)備的
MEGGER FREJA300繼電保護(hù)測(cè)試儀屬于工業(yè)級(jí)高精度檢測(cè)設(shè)備,測(cè)試精度處于行業(yè)領(lǐng)先水平,可滿(mǎn)足各類(lèi)對(duì)檢測(cè)數(shù)據(jù)準(zhǔn)確性要求較高的場(chǎng)景需求。該設(shè)備的高精度來(lái)源于多方面的設(shè)計(jì)優(yōu)勢(shì):首先是通道獨(dú)立架構(gòu)設(shè)計(jì),每個(gè)電壓、電流通道均為獨(dú)立輸出,不存在通道之間的信號(hào)串?dāng)_,可保障輸出信號(hào)的精度與穩(wěn)定性,輸出誤差遠(yuǎn)低于行業(yè)常規(guī)標(biāo)準(zhǔn)要求;其次是專(zhuān)屬輸入通道的優(yōu)化設(shè)計(jì),低位準(zhǔn)模擬輸入通道針對(duì)小信號(hào)采集做了專(zhuān)屬優(yōu)化,可精準(zhǔn)識(shí)別毫伏級(jí)的低幅值信號(hào),保障傳送器、變送器類(lèi)設(shè)備的測(cè)試精度,高位準(zhǔn)輸入通道針對(duì)高幅值信號(hào)做了抗干擾優(yōu)化,可在高電壓、大電流輸入場(chǎng)景下保障采集數(shù)據(jù)的準(zhǔn)確性,滿(mǎn)足瓦時(shí)計(jì)等電能計(jì)量設(shè)備的高精度測(cè)試需求;另外設(shè)備內(nèi)置高精度校準(zhǔn)模塊,可對(duì)輸出信號(hào)、采集信號(hào)進(jìn)行實(shí)時(shí)校準(zhǔn),避免溫漂、零漂等問(wèn)題對(duì)測(cè)試精度的影響,即使在極端高低溫的現(xiàn)場(chǎng)環(huán)境下,仍可保持穩(wěn)定的測(cè)試精度。該設(shè)備的精度可滿(mǎn)足電力行業(yè)主網(wǎng)繼電保護(hù)設(shè)備校驗(yàn)、核工業(yè)電氣系統(tǒng)安全檢測(cè)、軌道交通牽引供電系統(tǒng)故障排查、環(huán)保項(xiàng)目環(huán)境評(píng)估數(shù)據(jù)核驗(yàn)等高要求檢測(cè)場(chǎng)景的需求,測(cè)試數(shù)據(jù)可作為設(shè)備狀態(tài)判斷、項(xiàng)目合規(guī)性核驗(yàn)的有效依據(jù),適配各類(lèi)高精度工業(yè)檢測(cè)項(xiàng)目的要求。
MEGGER FREJA300繼電保護(hù)測(cè)試儀作為專(zhuān)業(yè)的繼電保護(hù)二次測(cè)試設(shè)備,廣泛應(yīng)用于電力、核工業(yè)、軌道交通、水務(wù)、環(huán)保等多個(gè)行業(yè)的繼電保護(hù)校驗(yàn)場(chǎng)景。電力行業(yè)中,可應(yīng)用于電網(wǎng)公司各級(jí)變電站的繼電保護(hù)裝置定期校驗(yàn)、發(fā)電廠機(jī)組側(cè)保護(hù)裝置的投產(chǎn)測(cè)試、智能變電站的IEC61850協(xié)議兼容保護(hù)裝置測(cè)試,也可用于電力試驗(yàn)研究院的繼電保護(hù)設(shè)備性能檢定、故障仿真模擬研究場(chǎng)景。核工業(yè)領(lǐng)域,可適配核電設(shè)施供配電系統(tǒng)繼電保護(hù)裝置的測(cè)試需求,滿(mǎn)足核電場(chǎng)景高可靠性測(cè)試要求。軌道交通行業(yè)中,可用于城市軌道交通牽引供電系統(tǒng)的保護(hù)裝置校驗(yàn)、高鐵沿線(xiàn)供電網(wǎng)繼電保護(hù)設(shè)備的現(xiàn)場(chǎng)巡檢測(cè)試,保障軌道交通供電系統(tǒng)的穩(wěn)定運(yùn)行。水務(wù)與環(huán)保行業(yè)中,可用于自來(lái)水廠、污水處理廠、大型環(huán)保設(shè)施的供配電系統(tǒng)繼電保護(hù)裝置的日常校驗(yàn)與故障排查,避免供電故障導(dǎo)致生產(chǎn)中斷。此外,設(shè)備支持寬溫度范圍作業(yè),既適合室內(nèi)實(shí)驗(yàn)室的批量校準(zhǔn)測(cè)試場(chǎng)景,也可攜帶至戶(hù)外作業(yè)現(xiàn)場(chǎng)開(kāi)展臨時(shí)測(cè)試、故障排查與預(yù)判工作,搭配LOCAL獨(dú)立操作模式,無(wú)需攜帶PC即可快速完成現(xiàn)場(chǎng)測(cè)試任務(wù)。